Staircase Calculator — Straight, L & U Room Fit
Compare straight, L-shaped and U-shaped stairs against your available room. Check riser splits, rotation, excess and straight-flight headroom in inches or millimetres.
“Fits” checks only the available rectangular room. Approach and exit space, doors, railings, structure and building regulations require separate review.
Straight staircase
Fits the available room
16 risers of 6.89 in · 15 treads of 11.02 in
- Riser / going
- 6.89 in / 11.02 in
- Step measure 2R + G
- 24.8 in
- Pitch
- 32.01°
Flight 1: 16 risers, 15 treads, 165.35 in run.
Floor opening above the straight flight
Minimum headroom: 81.69 in · target met. Minimum opening for the target above this flight: 132.28 in.
Approach floor clearance: 102.36 in. The opening ends at the upper floor and spans the full stair width. Slab thickness 7.87 in; target 78.74 in.
Your room
Adjust planning dimensions
These are planning preferences, not code limits. Going stays unchanged across all proposals.
Headroom is not checked for turned staircases: their floor-opening geometry needs a separate model.
Try the examples
How the planner works
Which staircase fits your room?
Compare a straight flight and two layouts with landings. The same floor height and planning dimensions produce three visible proposals.
Risers, going and landings
Risers, going and landings
Floor-to-floor height divided by the whole riser count gives the actual riser. A straight flight has one fewer tread: the upper floor forms the final step. Two flights with a landing have two fewer treads than risers.
A flight with n risers needs (n − 1) × going of horizontal run. The L layout uses a square landing. For U, the longest flight controls length; width includes both flights and the gap. The planner searches every whole count within your bounds and every allowed split. Going is never reduced to force a fit.
Headroom is measured at the highest covered tread under the slab, not along an imagined sloping line. The opening starts at the upper landing. An opening across the entire flight has no ceiling above it to measure. Approach and exit geometry need separate review.
The examples illustrate planning scenarios, not required dimensions. This tool plans straight treads and rectangular landings only: no winders, spirals, stringer cutting or structural design. Floor height is capped at 6 m and 120 risers. Preferred riser can range from 50 to 400 mm and going from 50 to 1,000 mm: arithmetic bounds, not recommended dimensions.
Check current local requirements and the full site with a qualified specialist. This calculator compares planning geometry and does not certify code compliance.